Cumpara de la ethercom.ro

Cablu UTP Cat6 NETSET LSOH cupru integral AWG23 [305m] (interior, Dca-s2,d2,a1) - NETSET


Cablu UTP Cat6 NETSET LSOH cupru integral AWG23 [305m] (interior, Dca-s2,d2,a1)
608.83 Lei

Disponibil

(03-10-2024)
Cumpara de la ethercom.ro

Produs vandut de ethercom.ro

(0)

Review(s)

Verifica toate preturile pentru acest produs : click aici


Distribuie pe :


Descriere :

Cumpara cablu utp cat6 netset de calitate.
Pe yeo poti sa gasesti cel mai bun pret pentru cablu utp cat6 netset

The NETSET BOX U/UTP cat 6 cable far exceeds the requirements for Category 6 twisted pair cables.
Specifications Name NETSET BOX U/UTP CAT 6 (indoor, Dca-s2,d2,a1) Code E1614 Structure Wires solid copper conductors with 0.54 mm diameter Wire insulation HDPE, 0.97 mm Sheath LSZHthickness: 0.55 mmexternal diameter: 5.9 mmcolor: gray Markings Cable Meter marks (error <0.5%) Wires (pairs) colors: white-orange/orange white-green/green white-blue/blue white-brown/brown Electrical parameters Wave impedance [Ω] 100 ±15 DC resistance [Ω/100m] 9.38 Test results Return Loss Frequency [MHz] Result (min.) [dB] 1 20,0 4 23,0 8 24,5 10 25,0 16 25,0 20 25,0 25 24,3 31,25 23,6 62,5 21,5 100 20,1 200 18 250 17,3 Attenuation Frequency [MHz] Result (min.) [dB] 1 2,03 4 3,78 8 5,32 10 5,95 16 8,47 25 9,51 31,25 10,67 62,5 15,38 100 19,8 200 28,98 250 32,85 NEXT (near end crosstalk) Frequency [MHz] Result (min.) [dB] 1 74,3 4 65,3 8 60,8 10 59,3 16 56,2 20 54,8 25 53,3 31,25 51,9 62,5 47,7 100 44,3 200 39,8 250 38,3 PSNEXT (power sum near end crosstalk) Frequency [MHz] Result (min.) [dB] 1 72,3 4 63,3 8 58,8 10 57,3 16 54,2 20 51,3 31,25 49,9 62,5 45,4 100 42,3 200 37,8 250 36,3 ELFEXT (equal level far end crosstalk loss testing) Frequency [MHz] Result (min.) [dB] 1 67,8 4 55,8 8 49,7 10 47,8 16 43,7 20 41,8 25 39,8 31,25 37,9 62,5 31,9 100 27,8 200 21,8 250 19,8 PSELFEXT (power sum equal level far end crosstalk loss testing) Frequency [MHz] Result (mi.
The minimum bending radius factor (radius to diameter ratio) is 8.
The NETSET UTP cat 5e E1614 cable can be used in a wide temperature range: -20oC...+70oC, and installed between 0oC and +50oC.
The manufacturer guarantees stability of parameters at least for 15 years, on the condition that the cable is packed, transported, installed, and used according to adequate European standards (among others E-79100 and EN 50174-1), within the permissible environmental conditions.
The cable comes with a 15-year warranty.
The NETSET BOX U/UTP CAT 6 E1614 LAN cable is manufactured in compliance with the following standards:EN50575:2014, EN60332-1-2:2004, EN50399:2011, EN60754-2:2014, EN 13501-6:2014. 4.0 mm, packed in 305-meter self dispensing box.
Distinguishing features of the NETSET BOX U/UTP CAT 6 cable: highest-quality materials, strict technological discipline confirmed by a 15-year quality guarantee, reaction to fire: Dca-s2,d2,a1 parameters far exceeding the requirements for Category 6 twisted pair cables preliminary quality control of materials and thorough tests of the final product, meter markers, deviation less than 0.5%, solid wires of 0.54 mm diameter, wire insulation made of homogeneous, colored HDPE; outer diameter: 0.97 mm; colors: white-green/green, white-orange/orange, white-brown/brown, white-blue/blue, pairs twisted together, outer diameter of ca.
Special insulation material makes it easier to attach RJ-45 connectors.
Its external diameter has been reduced to 5.9 mm, which considerably facilitates insertion of the cable into ducts and pipes.
The NETSET cable comes from the latest generation of UTP twisted pair cables.
Close-up of the cable View of the packaging Declaration of Performance (.pdf) The NETSET BOX U/UTP CAT 6 E1614 cable is the highest-quality twisted pair cable designed for professional data transmission systems inside buildings (structural wiring, LANs). in corridors, staircases or escape routes.
Reaction to fire: Dca - s2, d2, a1 Flame spread: Dca Smoke production: s2 Flaming droplets: d2 Gases acidity: a1 Thanks to the fulfillment of such high criteria, the twisted pair can be used in buildings and their parts that have increased fire resistance requirements, e.g.
NETSET cables are compliant with Construction Products Regulation (CPR) and EN 50575 harmonized European standard that specifies reaction to fire performance requirements, test and assessment methods for electric cables used for the supply of electricity and for control and communication purposes, which are intended for use in construction works and subject to performance requirements on reaction to fire.
The NETSET BOX U/UTP cat 6 cable far exceeds the requirements for Category 6 twisted pair cables


Uneori, aceste descrieri pot contine inadvertente. De asemenea, imaginea este informativa si poate contine accesorii neincluse in pachetele standard.
logo

  • Produsele tale vor fi disponibile pentru toti clientii nostri, in fiecare zi, pe yeo.ro
  • Vor fi promovate pe retele de socializare si bloguri
  • De asemenea, vom crea continut video pentru 20 de produse