INTRODUCTIONThis is a heavy-duty tester further improved in operability and portability. 320gFunctionRangeAccuracyRemarksDCV0.1V5% full scaleInput Impedance 20k 0.25/2.5/10/50V3% full scaleInput Impedance 20k 250/10003% full scaleInput Impedance 9k ACV10/50/250/1000V4% full scaleInput Impedance 9k/ V30Hz - 100Hz within 3% full scale(AC10V range)DCA50A3% full scaleVoltage drop 0.1V *12.5m/25m/0.25A3% full scaleVoltage drop 0.25V *1OHM2k/20k/2M 3% of arcCenter value 20Max value 2kRelease voltage 3V200M 5% of arcC10F-*2dB-10dB --- +22dB(for 10VAC) --- + 62dB-Input impedance 9k/VLi0 - 150mA at X 10 rangeCurrent across test pins0 - 15mA at X 1 range0 -150A at X 1k range0 - 1.5A at X 100k rangeMultimetru analogic YX-360TRD.
No condensationPower supply__ R6 x 2Fuse__ 0.5A/250V (20mm)Accessory__ Instruction manual, Hand strapDimension__159.5 x 129 x 41.5 mmWeight__ Approx.
Carrying case is not required.
Test leads can be neatly stored in the hard case.
Enables you to measure high resistance (up to maximum 200M ohm) with low voltage.
Capacity-measurement function(0.1F-10F).
Overload protection up to maximum 230V is provided.
High sensitive taut band meter with shock protection is equipped.
Provided with short strap for easy hand-carry.
The panel cover is free from dust and water drops.
SPECIFICATIONSMeter sensitivity__ 48ARange switch__ ManualAccuracy guaranteed temperature & humidity range__ 232\'c45-75% RHOperating temperature humidity range__ 0-40\'c, 80% RH Max. 2Protected by body cover that also serves as a stand.
Stabilized Indication :Used of a high quality inner magnet stabilizes the indication of an indication needle.
FEATURESIn conformity with IEC 1010 CAT.
Resistant to Drop Shock :A taut band meter adopted protects the meter section from drop shock.
Damage-Free Measurement :Measuring insulation resistance up to 200M ohm at a low voltage enables you to measure insulation resistance without damaging objects to be measured.
Additionally, the case also carries a hand-strap convenient for hand-carrying.
Capacitance Measurement :Capacitance of an AC capacitor used in an AC motor can be measured with C range switched to.
The lid of the case can be used as a stand, and reverse folded and fixed to the back together.
The connector less testing leads mounting shortens measuring time, and prevents loss or disconnection from occurring, thereby enabling reliability to be maintained.
The tester is vibration-resistant because of superiority in the designing of integral hard case, so that panel surface is free from scratches.
INTRODUCTIONThis is a heavy-duty tester further improved in operability and portability